{"_buckets": {"deposit": "bd1c53dd-69a4-4656-8573-c7d3c1d6c893"}, "_deposit": {"created_by": 18, "id": "42503", "owners": [18], "pid": {"revision_id": 0, "type": "depid", "value": "42503"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00042503", "sets": ["937"]}, "author_link": ["2690", "67545", "67546", "67541", "145", "67544", "67548", "67547", "67543"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-08-15", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "199", "bibliographicPageStart": "190", "bibliographicVolumeNumber": "1060", "bibliographic_titles": [{"bibliographic_title": "Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A relatively rapid and precise method is presented for the determination of lead in aqueous matrix. The method consists of analyte quantitation using the liquid electrode plasma-optical emission spectrometry (LEP-OES) coupled with selective separation/preconcentration by solid-phase extraction (SPE). The impact of operating variables on the retention of lead in SPEs such as pH, flow rate of the sample solution; type, volume, flow rate of the eluent; and matrix effects were investigated. Selective SPE-separation/preconcentration minimized the interfering effect due to manganese in solution and limitations in lead-detection in low-concentration samples by LEP-OES. The LEP-OES operating parameters such as the electrical conductivity of sample solution; applied voltage; on-time, off-time, pulse count for applied voltage; number of measurements; and matrix effects have also been optimized to obtain a distinct peak for the lead at λmax = 405.8 nm. The limit of detection (3σ) and the limit of quantification (10σ) for lead determination using the technique were found as 1.9 and 6.5 ng mL−1, respectively. The precision, as relative standard deviation, was lower than 5% at 0.1 μg mL−1 Pb, and the preconcentration factor was found to be 187. The proposed method was applied to the analysis of lead contents in the natural aqueous matrix (recovery rate: \u003e95%). The method accuracy was verified using certified reference material of wastewaters: SPS-WW1 and ERM-CA713. The results from LEP-OES were in good agreement with inductively coupled plasma optical emission spectrometry measurements of the same samples. The application of the method is rapid (≤5 min, without preconcentration) with a reliable detection limit at trace levels. © 2017 Elsevier B.V.", "subitem_description_type": "Abstract"}]}, "item_10001_description_6": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "著者所属: 金沢大学理工研究域物質化学系", "subitem_description_type": "Other"}, {"subitem_description": "Embargo Period 12 months", "subitem_description_type": "Other"}]}, "item_10001_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.24517/00048858", "subitem_identifier_reg_type": "JaLC"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier B.V."}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.jchromb.2017.06.016", "subitem_relation_type_select": "DOI"}}]}, "item_10001_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://www.elsevier.com/locate/issn/15700232"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.elsevier.com/locate/issn/15700232", "subitem_relation_type_select": "URI"}}]}, "item_10001_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © Elsevier B.V. (CC-BY NC ND) "}]}, "item_10001_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA1116375X", "subitem_source_identifier_type": "NCID"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1570-0232", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "牧, 輝弥"}, {"creatorName": "マキ, テルヤ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "2690", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70345601", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70345601"}, {"nameIdentifier": "70345601", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=70345601"}, {"nameIdentifier": "70345601", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070345601"}]}, {"creatorNames": [{"creatorName": "長谷川, 浩"}, {"creatorName": "ハセガワ, ヒロシ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "145", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90253335", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=90253335"}, {"nameIdentifier": "90253335", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=90253335"}, {"nameIdentifier": "90253335", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000090253335"}]}, {"creatorNames": [{"creatorName": "Suman, Barua", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "67541", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ismail M. M., Rahman", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "67543", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iftakharul, Alam ", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "67544", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Maho, Miyaguchi ", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "67545", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hikaru, Sawai ", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "67546", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Teruya, Maki ", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "67547", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiroshi, Hasegawa", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "67548", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-08-16"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-HASEGAWA-H-190.pdf", "filesize": [{"value": "518.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 518600.0, "url": {"label": "TE-PR-HASEGAWA-H-190.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/42503/files/TE-PR-HASEGAWA-H-190.pdf"}, "version_id": "61449f45-9153-4246-80b6-872a026beb16"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Lead", "subitem_subject_scheme": "Other"}, {"subitem_subject": "LEP-OES", "subitem_subject_scheme": "Other"}, {"subitem_subject": "On-site analysis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Preconcentration", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Selective separation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Solid-phase extraction", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead"}]}, "item_type_id": "10001", "owner": "18", "path": ["937"], "permalink_uri": "https://doi.org/10.24517/00048858", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-11-17"}, "publish_date": "2017-11-17", "publish_status": "0", "recid": "42503", "relation": {}, "relation_version_is_last": true, "title": ["Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead"], "weko_shared_id": 18}
Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead
https://doi.org/10.24517/00048858
https://doi.org/10.24517/00048858546b6fd6-eb84-41d4-8b40-2f9786edadb5
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-HASEGAWA-H-190.pdf (518.6 kB)
|
Item type | 学術雑誌論文 / Journal Article_default(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-11-17 | |||||
タイトル | ||||||
タイトル | Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Lead | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | LEP-OES | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | On-site analysis | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Preconcentration | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Selective separation | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Solid-phase extraction | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
ID登録 | ||||||
ID登録 | 10.24517/00048858 | |||||
ID登録タイプ | JaLC | |||||
著者 |
牧, 輝弥
× 牧, 輝弥× 長谷川, 浩× Suman, Barua× Ismail M. M., Rahman× Iftakharul, Alam× Maho, Miyaguchi× Hikaru, Sawai× Teruya, Maki× Hiroshi, Hasegawa |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A relatively rapid and precise method is presented for the determination of lead in aqueous matrix. The method consists of analyte quantitation using the liquid electrode plasma-optical emission spectrometry (LEP-OES) coupled with selective separation/preconcentration by solid-phase extraction (SPE). The impact of operating variables on the retention of lead in SPEs such as pH, flow rate of the sample solution; type, volume, flow rate of the eluent; and matrix effects were investigated. Selective SPE-separation/preconcentration minimized the interfering effect due to manganese in solution and limitations in lead-detection in low-concentration samples by LEP-OES. The LEP-OES operating parameters such as the electrical conductivity of sample solution; applied voltage; on-time, off-time, pulse count for applied voltage; number of measurements; and matrix effects have also been optimized to obtain a distinct peak for the lead at λmax = 405.8 nm. The limit of detection (3σ) and the limit of quantification (10σ) for lead determination using the technique were found as 1.9 and 6.5 ng mL−1, respectively. The precision, as relative standard deviation, was lower than 5% at 0.1 μg mL−1 Pb, and the preconcentration factor was found to be 187. The proposed method was applied to the analysis of lead contents in the natural aqueous matrix (recovery rate: >95%). The method accuracy was verified using certified reference material of wastewaters: SPS-WW1 and ERM-CA713. The results from LEP-OES were in good agreement with inductively coupled plasma optical emission spectrometry measurements of the same samples. The application of the method is rapid (≤5 min, without preconcentration) with a reliable detection limit at trace levels. © 2017 Elsevier B.V. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 著者所属: 金沢大学理工研究域物質化学系 | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Embargo Period 12 months | |||||
書誌情報 |
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences 巻 1060, p. 190-199, 発行日 2017-08-15 |
|||||
出版者 | ||||||
出版者 | Elsevier B.V. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1570-0232 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA1116375X | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.jchromb.2017.06.016 | |||||
権利 | ||||||
権利情報 | Copyright © Elsevier B.V. (CC-BY NC ND) | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.elsevier.com/locate/issn/15700232 | |||||
関連名称 | http://www.elsevier.com/locate/issn/15700232 | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |