WEKO3
インデックスリンク
アイテム
Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead
https://doi.org/10.24517/00048858
https://doi.org/10.24517/00048858546b6fd6-eb84-41d4-8b40-2f9786edadb5
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
| Item type | 学術雑誌論文 / Journal Article_default(1) | |||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2017-11-17 | |||||||||||||||||||||||||
| タイトル | ||||||||||||||||||||||||||
| タイトル | Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead | |||||||||||||||||||||||||
| 言語 | en | |||||||||||||||||||||||||
| 言語 | ||||||||||||||||||||||||||
| 言語 | eng | |||||||||||||||||||||||||
| キーワード | ||||||||||||||||||||||||||
| 主題Scheme | Other | |||||||||||||||||||||||||
| 主題 | Lead, LEP-OES, On-site analysis, Selective separation, Preconcentration, Solid-phase extraction | |||||||||||||||||||||||||
| 資源タイプ | ||||||||||||||||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||||||||||
| 資源タイプ | journal article | |||||||||||||||||||||||||
| ID登録 | ||||||||||||||||||||||||||
| ID登録 | 10.24517/00048858 | |||||||||||||||||||||||||
| ID登録タイプ | JaLC | |||||||||||||||||||||||||
| 著者 |
牧, 輝弥
× 牧, 輝弥
× 長谷川, 浩
× Suman, Barua
× Ismail M. M. Rahman
× Iftakharul, Alam
× Maho, Miyaguchi
× Hikaru, Sawai
× Teruya, Maki
× Hiroshi, Hasegawa
|
|||||||||||||||||||||||||
| 抄録 | ||||||||||||||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||||||||||||||
| 内容記述 | A relatively rapid and precise method is presented for the determination of lead in aqueous matrix. The method consists of analyte quantitation using the liquid electrode plasma-optical emission spectrometry (LEP-OES) coupled with selective separation/preconcentration by solid-phase extraction (SPE). The impact of operating variables on the retention of lead in SPEs such as pH, flow rate of the sample solution; type, volume, flow rate of the eluent; and matrix effects were investigated. Selective SPE-separation/preconcentration minimized the interfering effect due to manganese in solution and limitations in lead-detection in low-concentration samples by LEP-OES. The LEP-OES operating parameters such as the electrical conductivity of sample solution; applied voltage; on-time, off-time, pulse count for applied voltage; number of measurements; and matrix effects have also been optimized to obtain a distinct peak for the lead at λmax = 405.8 nm. The limit of detection (3σ) and the limit of quantification (10σ) for lead determination using the technique were found as 1.9 and 6.5 ng mL−1, respectively. The precision, as relative standard deviation, was lower than 5% at 0.1 μg mL−1 Pb, and the preconcentration factor was found to be 187. The proposed method was applied to the analysis of lead contents in the natural aqueous matrix (recovery rate: >95%). The method accuracy was verified using certified reference material of wastewaters: SPS-WW1 and ERM-CA713. The results from LEP-OES were in good agreement with inductively coupled plasma optical emission spectrometry measurements of the same samples. The application of the method is rapid (≤5 min, without preconcentration) with a reliable detection limit at trace levels. © 2017 Elsevier B.V. | |||||||||||||||||||||||||
| 内容記述 | ||||||||||||||||||||||||||
| 内容記述タイプ | Other | |||||||||||||||||||||||||
| 内容記述 | 著者所属: 金沢大学理工研究域物質化学系 | |||||||||||||||||||||||||
| 内容記述 | ||||||||||||||||||||||||||
| 内容記述タイプ | Other | |||||||||||||||||||||||||
| 内容記述 | Embargo Period 12 months | |||||||||||||||||||||||||
| 書誌情報 |
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences 巻 1060, p. 190-199, 発行日 2017-08-15 |
|||||||||||||||||||||||||
| 出版者 | ||||||||||||||||||||||||||
| 出版者 | Elsevier B.V. | |||||||||||||||||||||||||
| ISSN | ||||||||||||||||||||||||||
| 収録物識別子タイプ | ISSN | |||||||||||||||||||||||||
| 収録物識別子 | 1570-0232 | |||||||||||||||||||||||||
| 書誌レコードID | ||||||||||||||||||||||||||
| 収録物識別子タイプ | NCID | |||||||||||||||||||||||||
| 収録物識別子 | AA1116375X | |||||||||||||||||||||||||
| DOI | ||||||||||||||||||||||||||
| 関連タイプ | isVersionOf | |||||||||||||||||||||||||
| 識別子タイプ | DOI | |||||||||||||||||||||||||
| 関連識別子 | 10.1016/j.jchromb.2017.06.016 | |||||||||||||||||||||||||
| 権利 | ||||||||||||||||||||||||||
| 権利情報 | Copyright © Elsevier B.V. (CC-BY NC ND) | |||||||||||||||||||||||||
| 関連サイト | ||||||||||||||||||||||||||
| 識別子タイプ | URI | |||||||||||||||||||||||||
| 関連識別子 | http://www.elsevier.com/locate/issn/15700232 | |||||||||||||||||||||||||
| 関連名称 | http://www.elsevier.com/locate/issn/15700232 | |||||||||||||||||||||||||
| 著者版フラグ | ||||||||||||||||||||||||||
| 出版タイプ | AM | |||||||||||||||||||||||||
| 出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||||||||||||||||||||||