ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C. 医薬保健学域; 医学類・薬学類・医薬科学類・保健学類
  2. c 10. 学術雑誌掲載論文(医・保健)
  3. 1. 査読済論文(医学・保健)

Aneurysm clipping after partial endovascular embolization for ruptured cerebral aneurysms

http://hdl.handle.net/2297/40418
http://hdl.handle.net/2297/40418
50968cf9-fbeb-462a-8026-d7f72e4d3918
名前 / ファイル ライセンス アクション
ME-PR-YAMASHIMA-T-49.pdf ME-PR-YAMASHIMA-T-49.pdf (16.6 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Aneurysm clipping after partial endovascular embolization for ruptured cerebral aneurysms
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Nomura, Motohiro

× Nomura, Motohiro

WEKO 23346

Nomura, Motohiro

Search repository
Kida, Shinya

× Kida, Shinya

WEKO 23347
e-Rad 10214826

Kida, Shinya

Search repository
Uchiyama, Naoyuki

× Uchiyama, Naoyuki

WEKO 538
e-Rad 80293364
金沢大学研究者情報 80293364
研究者番号 80293364

Uchiyama, Naoyuki

Search repository
Yamashima, Tetsumori

× Yamashima, Tetsumori

WEKO 199
e-Rad 60135077
研究者番号 60135077

Yamashima, Tetsumori

Search repository
Yamashita, Junkoh

× Yamashita, Junkoh

WEKO 21834
e-Rad 90026948
研究者番号 90026948

Yamashita, Junkoh

Search repository
Yoshikawa, Jun

× Yoshikawa, Jun

WEKO 23348

Yoshikawa, Jun

Search repository
Matsui, Osamu

× Matsui, Osamu

WEKO 116
e-Rad 10019961
研究者番号 10019961

Matsui, Osamu

Search repository
書誌情報 Interventional Neuroradiology

巻 6, 号 SUPPL. 1, p. 49-58, 発行日 2000-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1591-0199
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 https://doi.org/10.1177/15910199000060s105
出版者
出版者 Japanese Society for Intravascular Neosurgery / Centauro srl
抄録
内容記述タイプ Abstract
内容記述 The aim of this study was to investigate the advantages and disadvantages of a two-stage treatment for ruptured cerebral aneurysms; partial embolization in acute stage followed by clipping in chronic stage of subarachnoid hemorrhage. Between April 1997 and August 1999, twenty ruptured cerebral aneurysms were initially treated endovasculary using Guglielmi detachable coils in our institution. Among them, complete embolization could not be achieved in 6 lesions. For these lesions, subsequent clipping was added. The radiological and operative findings, and outcomes of these cases were retrospectively reviewed. In 1 case, rerupture occurred during the endovascular procedure. Rerupture was not observed in any cases in the postembolization period. In 2 cases, complications related to the clipping but not the endovascular procedure occurred. These complications included impaired visual acuity for unverified reasons, and memory disturbance due to sacrifice of a perforator arising from the anterior communicating artery. In 3 cases, coil extraction was needed during the clipping, because the loops of the coil extended into the residual neck. Complications related to coil extraction were not observed in these 3 cases. Acute partial embolization of ruptured aneurysm appears to be effective for the prevention of subsequent rerupture during the subacute period, in which treatment for vasospasm should be performed, and the clipping procedure. However, in the case of relatively large aneurysms, small arteries or other normal structures behind the aneurysm cannot be observed directly during surgery, because of the immovability of the embolized aneurysm. Further, complete clip closure is impossible when loops of coil herniate into the neck. In such situations, coil extraction with or without resection of the aneurysm might be necessary, and care must be taken not to damage parent artery and surrounding vessels.
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 12:20:14.210678
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3