Development of a small wireless device for perspiration monitoring

https://doi.org/10.24517/00014365
https://doi.org/10.24517/00014365
cb145af8-65a4-4f2f-a835-6a64dd3d2937
名前 / ファイル ライセンス アクション
ME-PR-OGAI-K-391.pdf ME-PR-OGAI-K-391.pdf (665.3 kB)
license.icon
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Development of a small wireless device for perspiration monitoring
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
ID登録
ID登録 10.24517/00014365
ID登録タイプ JaLC
著者 Ogai, Kazuhiro

× Ogai, Kazuhiro

WEKO 24398
金沢大学研究者情報 40706983
研究者番号 40706983

Ogai, Kazuhiro

Search repository
Fukuoka, Masakazu

× Fukuoka, Masakazu

WEKO 24897

Fukuoka, Masakazu

Search repository
Kitamura, Kei-ichiro

× Kitamura, Kei-ichiro

WEKO 324
e-Rad 80283117
金沢大学研究者情報 80283117
研究者番号 80283117

Kitamura, Kei-ichiro

Search repository
Uchide, Kiyoshi

× Uchide, Kiyoshi

WEKO 558
研究者番号 00168709

Uchide, Kiyoshi

Search repository
Nemoto, Tetsu

× Nemoto, Tetsu

WEKO 577
e-Rad 90126243
研究者番号 90126243

Nemoto, Tetsu

Search repository
著者別表示 大貝, 和裕

× 大貝, 和裕

大貝, 和裕

Search repository
北村, 敬一郎

× 北村, 敬一郎

北村, 敬一郎

Search repository
打出, 喜義

× 打出, 喜義

打出, 喜義

Search repository
根本, 鉄

× 根本, 鉄

根本, 鉄

Search repository
書誌情報 Medical Engineering and Physics

巻 38, 号 4, p. 391-397, 発行日 2016-04-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1350-4533
NCID
収録物識別子タイプ NCID
収録物識別子 AA10986246
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1016/j.medengphy.2015.12.009
出版者
出版者 Elsevier
抄録
内容記述タイプ Abstract
内容記述 A small and wireless device that can capture the temporal pattern of perspiration by a novel structure of water vapor collection combined with reusable desiccant has been developed. The novel device consists of a small cylindrical case with a temperature/relative humidity sensor, battery-driven data logger, and silica gel (desiccant). Water vapor of perspiration was detected by the change in relative humidity and then adsorbed by silica gel, allowing continuous recording of perspiration within a closed and wireless chamber, which has not been previously achieved. By comparative experiments using the commercially-available perspiration monitoring device, the developed device could measure perspiration as efficiently as the conventional one, with a normalized cross coefficient of 0.738 with 6 s delay and the interclass correlation coefficient [ICC(2, 1)] of 0.84. These results imply a good agreement between the conventional and developed devices, and thus suggest the applicability of the developed device for perspiration monitoring. © 2015 IPEM.
内容記述
内容記述タイプ Other
内容記述 Embargo Period 12 months
権利
権利情報 Copyright © Elsevier (CC-BY NC ND)
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連URI
識別子タイプ URI
関連識別子 http://www.elsevier.com/locate/issn/13504533
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 08:49:02.394083
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3