WEKO3
インデックスリンク
アイテム
Determination of Atmospheric Nitrobenzanthrones by High-Performance Liquid Chromatography with Chemiluminescence Detection
http://hdl.handle.net/2297/29315
http://hdl.handle.net/2297/29315d01fb705-f772-4af3-a1e9-361f90acded8
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-04 | |||||
タイトル | ||||||
タイトル | Determination of Atmospheric Nitrobenzanthrones by High-Performance Liquid Chromatography with Chemiluminescence Detection | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Tang, Ning
× Tang, Ning× Taga, Rina× Hattori, Tetsuyuki× Tamura, Kenji× Toriba, Akira× Kizu, Ryoichi× Hayakawa, Kazuichi |
|||||
書誌情報 |
Analytical Sciences 巻 20, 号 1, p. 119-123, 発行日 2004-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0910-6340 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10500785 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.2116/analsci.20.119 | |||||
出版者 | ||||||
出版者 | Japan Society for Analytical Chemistry = 日本分析化学会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A method using high-performance liquid chromatography with chemiluminescence detection was developed for analyzing mutagenic nitrobenzanthrone (NBA) isomers in airborne particulates. The method was a modification of our previously described method for analyzing nitropolycyclic aromatic hydrocarbons (NPAHs). The pretreatment and reducing conditions for 1-, 2-, 3- and 10-NBAs were the same as those for NPAHs. In order to separate these NBA isomers, we used a polymeric-type ODS column (Cosmosil 5C-18MS); a mixture of 40% acetonitrile and 60% 10 mM imidazole-HClO4 buffer was employed as the mobile phase at a flow rate of 1 mL/min. The isomers of 1-, 2-, 3- and 10-NBA were determined in chemiluminescence with linear calibration graphs from 0.1 to 4 pmol, from 200 to 4000 pmol, from 1 to 50 pmol and from 10 to 400 pmol, respectively. The detection limits (S/N = 3) of 1-, 2-, 3- and 10-NBA isomers were 0.02 pmol, 35 pmol, 0.3 pmol and 3 pmol, respectively. The method was used to analyze airborne particulates at a heavy traffic site in Kanazawa. 2- and 3-NBAs were detected in the extracts of the particulates, while 1-NBA and 10-NBA were not detected. The atmospheric concentrations of 2- and 3-NBAs were 1.83 pmol/m3 and 24.7 fmol/m3, respectively. | |||||
権利 | ||||||
権利情報 | Copyright (c) 2004 by The Japan Society for Analytical Chemistry | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jsac.or.jp/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://japanlinkcenter.org/JST.JSTAGE/analsci/20.119 |