WEKO3
インデックスリンク
アイテム
A new on-line sample preparation system for the liquid chromatography/time- of-flight mass spectrometry simultaneous analysis of pesticides in river water
http://hdl.handle.net/2297/29316
http://hdl.handle.net/2297/29316d370cdfc-57ed-4baf-98be-c4071020a9d9
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-04 | |||||
タイトル | ||||||
タイトル | A new on-line sample preparation system for the liquid chromatography/time- of-flight mass spectrometry simultaneous analysis of pesticides in river water | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Sasaki, Hideki
× Sasaki, Hideki× Yonekubo, Jun× Hayakawa, Kazuichi |
|||||
書誌情報 |
Analytical Sciences 巻 22, 号 6, p. 835-840, 発行日 2006-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0910-6340 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10500785 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.2116/analsci.22.835 | |||||
出版者 | ||||||
出版者 | Japan Society for Analytical Chemistry = 日本分析化学会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Current on-line solid-phase extraction methods combined with HPLC for shortening the clean-up operation are not suitable for simultaneously detecting compounds that have a wide variety of hydrophobicities. To solve these problems, we designed a new on-line sample preparation system. The system consists of an eluting pump, a mixing TEE connector, a 10-port 2-position valve and a solid-phase extraction precolumn. The eluate from the precolumn is diluted with a weak solvent from the HPLC at the TEE connection to load low hydrophobic compounds onto the analytical column. The proposed on-line sample preparation system was successfully applied to the simultaneous analysis of 21 pesticides in river water using LC/TOF-MS. In this method, the recoveries from river water samples were 67 to 126% (mean 83%), the reproducibility (CV%) was in the range from 1.1 to 11% (mean 5.6%), the calibration curve was linear in the range from 1 ppb to 500 ppb (r > 0.999) and the detection limits (S/N = 3) were in the range from 0.0034 ppb (daimuron) to 3.3 ppb (oxine-copper). 2006 © The Japan Society for Analytical Chemistry. | |||||
権利 | ||||||
権利情報 | Copyright (c) 2006 by The Japan Society for Analytical Chemistry | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jsac.or.jp/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://japanlinkcenter.org/JST.JSTAGE/analsci/22.835 |