WEKO3
インデックスリンク
アイテム
An optical rotatory detector for high-performance liquid chromatography using polarization modulation
http://hdl.handle.net/2297/29286
http://hdl.handle.net/2297/292864206ada0-1140-4724-a3d8-a53fb1db9a53
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2017-10-04 | |||||
| タイトル | ||||||
| タイトル | An optical rotatory detector for high-performance liquid chromatography using polarization modulation | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| 著者 |
Yamamoto, Atsushi
× Yamamoto, Atsushi× Kawai, Mio× Sakamoto, Mitsunori× Kodama, Shuji× Hayakawa, Kazuichi |
|||||
| 書誌情報 |
Analytical Sciences 巻 24, 号 3, p. 361-364, 発行日 2008-03-01 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0910-6340 | |||||
| NCID | ||||||
| 収録物識別子タイプ | NCID | |||||
| 収録物識別子 | AA10500785 | |||||
| DOI | ||||||
| 関連タイプ | isIdenticalTo | |||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.2116/analsci.24.361 | |||||
| 出版者 | ||||||
| 出版者 | Japan Society for Analytical Chemistry = 日本分析化学会 | |||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | A sensitive and variable-wavelength optical rotatory (OR) detector for high-performance liquid chromatography is presented. This design is entirely different from that of conventional OR detectors consisting of a crossed polarizer pair. By placing a polarizing prism and a retardation plate into a commercial circular dichroism (CD) detector, the OR signal was obtained. The Mueller matrix approach was used to prove the principle of the OR signal appearance. Sugars and 4-androstene-3,17-dione were chosen as test compounds. The limit of detection was below 0.5 μg of injected sucrose at 260 nm, which was superior to that obtained with a conventional OR detector. For 4-androstene-3,17-dione, which is CD active, and shows a large anomalous OR dispersion curve, our detector gave a large OR signal with approximately half the intensity of the CD signal at 340 nm. 2008 © The Japan Society for Analytical Chemistry. | |||||
| 権利 | ||||||
| 権利情報 | Copyright (c) 2008 by The Japan Society for Analytical Chemistry | |||||
| 著者版フラグ | ||||||
| 出版タイプ | VoR | |||||
| 出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
| 関連URI | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | http://www.jsac.or.jp/ | |||||
| 関連URI | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | https://japanlinkcenter.org/JST.JSTAGE/analsci/24.361 | |||||