Wideband phase-locked loop circuit with real-time phase correction for frequency modulation atomic force microscopy
https://doi.org/10.24517/00039994
https://doi.org/10.24517/000399944d1efd8d-f4b5-4042-bf39-6ec34478c67d
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 学術雑誌論文 / Journal Article(1) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2017-10-06 | |||||||||
タイトル | ||||||||||
タイトル | Wideband phase-locked loop circuit with real-time phase correction for frequency modulation atomic force microscopy | |||||||||
言語 | ||||||||||
言語 | eng | |||||||||
資源タイプ | ||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
資源タイプ | journal article | |||||||||
ID登録 | ||||||||||
ID登録 | 10.24517/00039994 | |||||||||
ID登録タイプ | JaLC | |||||||||
著者 |
Fukuma, Takeshi
× Fukuma, Takeshi× Yoshioka, Shunsuke× Asakawa, Hitoshi |
|||||||||
著者別表示 |
福間, 剛士
× 福間, 剛士
× 淺川, 雅
|
|||||||||
書誌情報 |
Review of Scientific Instruments 巻 82, 号 7, p. 73707, 発行日 2011-07-01 |
|||||||||
ISSN | ||||||||||
収録物識別子タイプ | ISSN | |||||||||
収録物識別子 | 0034-6748 | |||||||||
NCID | ||||||||||
収録物識別子タイプ | NCID | |||||||||
収録物識別子 | AA00817730 | |||||||||
DOI | ||||||||||
関連タイプ | isIdenticalTo | |||||||||
識別子タイプ | DOI | |||||||||
関連識別子 | 10.1063/1.3608447 | |||||||||
出版者 | ||||||||||
出版者 | American Institute of Physics (AIP) | |||||||||
抄録 | ||||||||||
内容記述タイプ | Abstract | |||||||||
内容記述 | We have developed a wideband phase-locked loop (PLL) circuit with real-time phase correction for high-speed and accurate force measurements by frequency modulation atomic force microscopy (FM-AFM) in liquid. A high-speed operation of FM-AFM requires the use of a high frequency cantilever which, however, increases frequency-dependent phase delay caused by the signal delay within the cantilever excitation loop. Such phase delay leads to an error in the force measurements by FM-AFM especially with a low Q factor. Here, we present a method to compensate this phase delay in real time. Combined with a wideband PLL using a subtraction-based phase comparator, the method allows to perform an accurate and high-speed force measurement by FM-AFM. We demonstrate the improved performance by applying the developed PLL to three-dimensional force measurements at a mica/water interface. © 2011 American Institute of Physics. | |||||||||
権利 | ||||||||||
権利情報 | © 2011 American Institute of Physics | |||||||||
著者版フラグ | ||||||||||
出版タイプ | VoR | |||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||
関連URI | ||||||||||
識別子タイプ | URI | |||||||||
関連識別子 | http://rsi.aip.org/resource/1/rsinak/v82/i7/p073707_s1?isAuthorized=no |