ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. G. 附属病院
  2. g 10. 学術雑誌掲載論文
  3. 1. 査読済論文

Objective evaluation of cerebrovascular reactivity for acetazolamide predicts cerebral hyperperfusion after carotid artery stenting: Comparison with region of interest methods

https://doi.org/10.24517/00050486
https://doi.org/10.24517/00050486
1eae4727-3659-4d98-8fc5-613090d9e18f
名前 / ファイル ライセンス アクション
ME-PR-MISAKI-K-2018.pdf ME-PR-MISAKI-K-362.pdf (723.3 kB)
license.icon
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2018-04-13
タイトル
タイトル Objective evaluation of cerebrovascular reactivity for acetazolamide predicts cerebral hyperperfusion after carotid artery stenting: Comparison with region of interest methods
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
ID登録
ID登録 10.24517/00050486
ID登録タイプ JaLC
著者 Misaki, Koichi

× Misaki, Koichi

WEKO 74028
e-Rad 20507082

Misaki, Koichi

Search repository
Uchiyama, Naoyuki

× Uchiyama, Naoyuki

WEKO 69881
e-Rad 80293364

Uchiyama, Naoyuki

Search repository
Inaki, Anri

× Inaki, Anri

WEKO 22400
e-Rad 40645131

Inaki, Anri

Search repository
Kinuya, Seigo

× Kinuya, Seigo

WEKO 22513
e-Rad 20281024

Kinuya, Seigo

Search repository
Nambu, Iku

× Nambu, Iku

WEKO 45599
e-Rad 80735465

Nambu, Iku

Search repository
Kamide, Tomoya

× Kamide, Tomoya

WEKO 74033

Kamide, Tomoya

Search repository
Mohri, Masanao

× Mohri, Masanao

WEKO 44968

Mohri, Masanao

Search repository
Hayashi, Yasuhiko

× Hayashi, Yasuhiko

WEKO 12082
e-Rad 50324124
金沢大学研究者情報 50324124
研究者番号 50324124

Hayashi, Yasuhiko

Search repository
Nakada, Mitsutoshi

× Nakada, Mitsutoshi

WEKO 74036
e-Rad 20334774

Nakada, Mitsutoshi

Search repository
著者別表示 見崎, 孝一

× 見崎, 孝一

見崎, 孝一

Search repository
内山, 尚之

× 内山, 尚之

内山, 尚之

Search repository
稲木, 杏吏

× 稲木, 杏吏

稲木, 杏吏

Search repository
絹谷, 清剛

× 絹谷, 清剛

絹谷, 清剛

Search repository
林, 康彦

× 林, 康彦

林, 康彦

Search repository
中田, 光俊

× 中田, 光俊

中田, 光俊

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学附属病院脳神経外科
書誌情報 Journal of Neuroradiology

巻 45, 号 6, p. 362-367, 発行日 2018-10
ISSN
収録物識別子タイプ ISSN
収録物識別子 0150-9861
NCID
収録物識別子タイプ NCID
収録物識別子 AA0025864X
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1016/j.neurad.2018.02.008
出版者
出版者 Elsevier Masson SAS
抄録
内容記述タイプ Abstract
内容記述 Background and purpose: Hemodynamic impairments are considered risk factors of cerebral hyperperfusion after carotid artery stenting (CAS); measurement by Single-photon emission computed tomography (SPECT) using a subjective region of interest (ROI) method lacks consistency and reproducibility. Materials and methods: The present study compared objective perfusion analysis (stereotactic extraction estimation [SEE] method) with the ROI method for preoperative SPECT to predict the hyperperfusion phenomenon (HPP) after CAS. Preoperative resting asymmetry index (cerebral blood flow [CBF] ratio from the affected to unaffected hemisphere) and cerebrovascular reactivity (CVR) to acetazolamide were measured by N-isopropyl-p-[123I]-iodoamphetamine SPECT using the SEE and ROI method in 84 patients. CBF was also measured the day after CAS. Perfusion data with the highest area under the curve (AUC) by receiver-operating characteristic (ROC) analysis was considered a perfusion risk factor of HPP. Multivariate analyses for clinical characteristics and perfusion risk factors were performed to determine predictors of HPP. Results: The HPP was observed in 10 patients (11.9%). Female sex, contralateral stenosis, and degree of stenosis were significantly associated with HPP development on univariate analysis, and symptomatic stenosis was not found to be a significant factor. On SPECT analysis, CVR in the MCA area by SEE method had the highest AUC (0.981). Multivariate analysis showed that CVR in the MCA area was a significant predictor of HPP (P = 0.041). To predict hyperperfusion, the ROC curve of the CVR showed a cutoff value of –0.60%, sensitivity of 94.6%, and specificity of 100% (P < 0.001). Conclusions: Objective SEE method had better a predictive capability than ROI method to identify risk of hyperperfusion after CAS. © 2018 Elsevier Masson SAS
内容記述
内容記述タイプ Other
内容記述 Embargo Period 12 months
権利
権利情報 Copyright © 2018 Elsevier Masson SAS
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連URI
識別子タイプ URI
関連識別子 http://www.elsevier.com/locate/issn/00142980
関連名称 http://www.elsevier.com/locate/issn/00142980
関連URI
識別子タイプ URI
関連識別子 https://seikagaku.jbsoc.or.jp/
関連名称 https://seikagaku.jbsoc.or.jp/
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 15:01:13.485872
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3