WEKO3
インデックスリンク
アイテム
An optimal spot-electrodes array for electrical impedance cardiography through determination of impedance mapping of a regional area along the medial line on the thorax
http://hdl.handle.net/2297/6248
http://hdl.handle.net/2297/6248221ffa14-3e7d-4722-879c-bef72eff0cb1
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | An optimal spot-electrodes array for electrical impedance cardiography through determination of impedance mapping of a regional area along the medial line on the thorax | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Igarashi, Akira
× Igarashi, Akira× Nogawa, Masamichi× Yamakoshi, Takehiro× Tanaka, Shinobu× Yamakoshi, Ken-ichi |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 野川, 雅道 | |||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学大学院自然科学研究科知的システム創成 | |||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | (財)石川県産業創出支援機構(ISICO) | |||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 石川ハイテク・センシング・クラスター | |||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学工学部人間・機械工学科人間適応制御研究室 | |||||
書誌情報 |
Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings 巻 4030441, p. 3202-3205, 発行日 2006-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0589-1019 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1109/iembs.2006.260748 | |||||
その他の識別子 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 4030441 | |||||
出版者 | ||||||
出版者 | Institute of Electrical and Electronics Engineers (IEEE) | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Electrical impedance or admittance cardiography is a simple method for non-invasive, continuous measurement the stroke volume and cardiac output. For the Electrical impedance cardiography, the band-electrodes array proposed by Kubicek et al has been widely used, and various spot-electrodes array have been experimented in search of a less uncomfortable and equally reliable electrodes array that is easier to attach. From the uniformity of current distribution on the thorax, we have reinvestigated focusing on the measurement of contour maps of static and pulsatile components of a regional area along the medial line on the frontal part of the thorax. Consequently, the appropriate electrodes locations for current injection were determined as the back of an ear and on the lower abdomen, while those for voltage pick-up was on the medial portion at the level of clavicle and on the portion above the xiphisternum. Preliminary comparison experiments between the cardiac output values obtained by the electrical impedance cardiography and by a pulse dye-densitometry showed a fairy good agreement. © 2006 IEEE. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |