WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "0b73bd21-591c-402c-8202-1b6afb667e5f"}, "_deposit": {"created_by": 3, "id": "13735", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "13735"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00013735", "sets": ["1134"]}, "author_link": ["22999", "22998", "22995", "120", "22997", "22996", "23000", "20089"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "140", "bibliographicPageStart": "136", "bibliographicVolumeNumber": "19", "bibliographic_titles": [{"bibliographic_title": "医用画像情報学会雑誌 = Medical Imaging and Information Sciences"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We analysed of the images generated with multi-slice CT in the longitudinal direction (Z) and assessed the noise equivalent quanta (NEQ)evaluation. Evaluation of image quality in NEQ, was possible to accuracy of reappearance in low at high frequency characteristics. In addition, NEQ information was confirmed of usefulness in compared with Winer spectra and MTF method. Examination results suggest that the quantitative analysis in characteristics of image noise and image resolution at multi-slice CT images can provide an optimal parameter for improving quality of images in clinical data.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "医用画像情報学会 = MII: Japan Society of Medical Imaging and Information Sciences"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.11318/mii1984.19.136", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/mii/-char/ja/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.mii-sci.jp/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 医用画像情報学会 MII: Japan Society of Medical Imaging and Information Sciences"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10156808", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0910-1543", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "五味, 勉"}], "nameIdentifiers": [{"nameIdentifier": "22995", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "春日, 敏夫"}], "nameIdentifiers": [{"nameIdentifier": "22996", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "角谷, 眞澄"}], "nameIdentifiers": [{"nameIdentifier": "22997", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40115225", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040115225"}]}, {"creatorNames": [{"creatorName": "宮地, 利明"}], "nameIdentifiers": [{"nameIdentifier": "120", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80324086", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80324086"}, {"nameIdentifier": "80324086", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=80324086"}, {"nameIdentifier": "80324086", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080324086"}]}, {"creatorNames": [{"creatorName": "越田, 吉郎"}], "nameIdentifiers": [{"nameIdentifier": "20089", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90020023", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=90020023"}, {"nameIdentifier": "90020023", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000090020023"}]}, {"creatorNames": [{"creatorName": "安藤, 隆"}], "nameIdentifiers": [{"nameIdentifier": "22998", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上田, 仁"}], "nameIdentifiers": [{"nameIdentifier": "22999", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐々木, 祥之"}], "nameIdentifiers": [{"nameIdentifier": "23000", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-MITATI-T-136.pdf", "filesize": [{"value": "967.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 967000.0, "url": {"label": "ME-PR-MITATI-T-136.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/13735/files/ME-PR-MITATI-T-136.pdf"}, "version_id": "666fedc3-584c-4ad7-bd7d-e648248f0f99"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "multi-slice CT", "subitem_subject_scheme": "Other"}, {"subitem_subject": "NEQ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "image quality", "subitem_subject_scheme": "Other"}, {"subitem_subject": "image analysis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "quantitative analysis", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "NEQを用いたマルチスライスCTの体軸方向における画質評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "NEQを用いたマルチスライスCTの体軸方向における画質評価"}, {"subitem_title": "Evaluation of Characteristic of Longitudinal Direction in Multi-slice CT using NEQ", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/36647", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "13735", "relation": {}, "relation_version_is_last": true, "title": ["NEQを用いたマルチスライスCTの体軸方向における画質評価"], "weko_shared_id": -1}
NEQを用いたマルチスライスCTの体軸方向における画質評価
http://hdl.handle.net/2297/36647
http://hdl.handle.net/2297/36647df264445-c2ff-4097-9ce6-0b2a2f3ad176
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-MITATI-T-136.pdf (967.0 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | NEQを用いたマルチスライスCTの体軸方向における画質評価 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Evaluation of Characteristic of Longitudinal Direction in Multi-slice CT using NEQ | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
五味, 勉
× 五味, 勉× 春日, 敏夫× 角谷, 眞澄× 宮地, 利明× 越田, 吉郎× 安藤, 隆× 上田, 仁× 佐々木, 祥之 |
|||||
書誌情報 |
医用画像情報学会雑誌 = Medical Imaging and Information Sciences 巻 19, 号 3, p. 136-140, 発行日 2002-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0910-1543 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10156808 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.11318/mii1984.19.136 | |||||
出版者 | ||||||
出版者 | 医用画像情報学会 = MII: Japan Society of Medical Imaging and Information Sciences | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We analysed of the images generated with multi-slice CT in the longitudinal direction (Z) and assessed the noise equivalent quanta (NEQ)evaluation. Evaluation of image quality in NEQ, was possible to accuracy of reappearance in low at high frequency characteristics. In addition, NEQ information was confirmed of usefulness in compared with Winer spectra and MTF method. Examination results suggest that the quantitative analysis in characteristics of image noise and image resolution at multi-slice CT images can provide an optimal parameter for improving quality of images in clinical data. | |||||
権利 | ||||||
権利情報 | Copyright © 医用画像情報学会 MII: Japan Society of Medical Imaging and Information Sciences | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/mii/-char/ja/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.mii-sci.jp/ |