Evaluation of the effectiveness of X-ray protective aprons in experimental and practical fields

http://hdl.handle.net/2297/39049
http://hdl.handle.net/2297/39049
0047e197-fd7b-46f5-8ff3-8933664e36d5
名前 / ファイル ライセンス アクション
ME-PR-MORI-H-158.pdf ME-PR-MORI-H-158.pdf (726.5 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Evaluation of the effectiveness of X-ray protective aprons in experimental and practical fields
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Mori, Hiroshige

× Mori, Hiroshige

WEKO 24124

Mori, Hiroshige

Search repository
Koshida, Kichiro

× Koshida, Kichiro

WEKO 20089
e-Rad 90020023
研究者番号 90020023

Koshida, Kichiro

Search repository
Ishigamori, Osamu

× Ishigamori, Osamu

WEKO 24125

Ishigamori, Osamu

Search repository
Matsubara, Kosuke

× Matsubara, Kosuke

WEKO 521
金沢大学研究者情報 30507372
研究者番号 30507372

Matsubara, Kosuke

Search repository
書誌情報 Radiological Physics and Technology

巻 7, 号 1, p. 158-166, 発行日 2014-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0341
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1007/s12194-013-0246-x
出版者
出版者 Springer-Verlag
抄録
内容記述タイプ Abstract
内容記述 Few practical evaluation studies have been conducted on X-ray protective aprons in workplaces. We examined the effects of exchanging the protective apron type with regard to exposure reduction in experimental and practical fields, and discuss the effectiveness of X-ray protective aprons. Experimental field evaluations were performed by the measurement of the X-ray transmission rates of protective aprons. Practical field evaluations were performed by the estimation of the differences in the transit doses before and after the apron exchange. A 0.50-mm lead-equivalent-thick non-lead apron had the lowest transmission rate among the 7 protective aprons, but weighed 10.9 kg and was too heavy. The 0.25 and 0.35-mm lead-equivalent-thick non-lead aprons differed little in the practical field of interventional radiology. The 0.35-mm lead apron had lower X-ray transmission rates and transit doses than the 0.25-mm lead-equivalent- thick non-lead apron, and each of these differences exceeded 8% in the experimental field and approximately 0.15 mSv/month in the practical field of computed tomography (p <0.01). Therefore, we concluded that the 0.25-mm lead-equivalent-thick aprons and 0.35-mm lead apron are effective for interventional radiology operators and computed tomography nurses, respectively. © The Author(s) 2013.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 00:52:28.395842
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3