Automatic Anatomical Labeling Method of Cerebral Arteries in MR-Angiography Data Set

https://doi.org/10.24517/00050490
https://doi.org/10.24517/00050490
85a208d6-4169-4cb0-a868-07db360edfe8
名前 / ファイル ライセンス アクション
ME-PR-TAKEMURA-A-187.pdf ME-PR-TAKEMURA-A-187.pdf (4.4 MB)
license.icon
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-04-13
タイトル
タイトル Automatic Anatomical Labeling Method of Cerebral Arteries in MR-Angiography Data Set
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
ID登録
ID登録 10.24517/00050490
ID登録タイプ JaLC
著者 Takemura, Akihiro

× Takemura, Akihiro

WEKO 74160
e-Rad 70313674

Takemura, Akihiro

Search repository
Suzuki, Masayuki

× Suzuki, Masayuki

WEKO 20280
e-Rad 70111325

Suzuki, Masayuki

Search repository
Harauchi, Hajime

× Harauchi, Hajime

WEKO 74096

Harauchi, Hajime

Search repository
Okumura, Yusuke

× Okumura, Yusuke

WEKO 74097

Okumura, Yusuke

Search repository
著者別表示 武村, 哲浩

× 武村, 哲浩

武村, 哲浩

Search repository
鈴木, 正行

× 鈴木, 正行

鈴木, 正行

Search repository
原内, 一

× 原内, 一

原内, 一

Search repository
奥村, 祐悠

× 奥村, 祐悠

奥村, 祐悠

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学医薬保健研究域保健学系
書誌情報 医学物理
en : Japanese journal of medical physics

巻 26, 号 4, p. 187-198, 発行日 2006
ISSN
収録物識別子タイプ ISSN
収録物識別子 1345-5354
NCID
収録物識別子タイプ NCID
収録物識別子 AA11580542
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.11323/jjmp2000.26.4_187
出版者
出版者 Japan Society of Medical Physics 日本医学物理学会
抄録
内容記述タイプ Abstract
内容記述 To improve the accuracy and robustness of 2D/3D registration of digital subtraction angiography images and magnetic resonance angiography (MRA) data , we have developed an automatic method for anatomical labeling of the cerebral arteries in MRA data. The anatomical labeling method is a location-based method which segments an artery tree to branches and classifies the branches into labeled segments , i.e., internal carotid arteries (ICA), basilar artery (BA), middle cerebral arteries (MCA) , Al segments of the anterior cerebral artery (ACA(A1)), other segments of the anterior cerebral artery (ACA), posterior communication arteries (PcomA) and posterior cerebral arteries (PCA), according to their location. Arteries were extracted from MRA data for this labeling method by the region-growing technique . Fifteen cases were examined to evaluate the method accuracy. The number of correctly segmented voxels in each artery segment was determined, and the correct labeling percentage was calculated based on the total number of voxels of the artery . Mean percentages were as follows: ACA, 82.7%; Right (R-) ACA(A1) , 47.1%; Left (L-) ACA(A1), 46.1%; R-MCA, 80.4%; L-MCA, 74.1%; R-PcomA , 0.0%; L-PcomA, 3.3%; R-PCA, 60.3%; LPCA, 66.9%; R-ICA, 90.7%; L-ICA, 90.7%; BA, 89.9%; and total arteries, 84.1%. The ACA, MCA, ICA and BA were consistently identified correctly .
権利
権利情報 Copyright © Japan Society of Medical Physics 日本医学物理学会
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連URI
識別子タイプ URI
関連識別子 http://www.jsmp.org/
関連名称 http://www.jsmp.org/
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 17:35:35.153642
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3